{"id":673,"date":"2022-12-02T19:39:52","date_gmt":"2022-12-02T11:39:52","guid":{"rendered":"https:\/\/www.qbkg.com\/?p=673"},"modified":"2024-08-30T21:41:36","modified_gmt":"2024-08-30T13:41:36","slug":"tmax-series-moulded-case-circuit-breaker","status":"publish","type":"post","link":"https:\/\/www.xdele.cn\/en\/tmax-series-moulded-case-circuit-breaker.html","title":{"rendered":"CYM3T(TMAX) Series Moulded Case Circuit Breaker"},"content":{"rendered":"<p>SACE T Les disjoncteurs en bo\u00eetier moul\u00e9 Generation garantissent un niveau de performance extr\u00eamement \u00e9lev\u00e9 tout en \u00e9tant de plus en plus petits, simples \u00e0 installer et capables d&#8217;offrir des garanties de s\u00e9curit\u00e9 toujours plus \u00e9lev\u00e9es pour l&#8217;op\u00e9rateur.<\/p>\r\n<p>En plus d&#8217;\u00eatre id\u00e9aux pour la distribution secondaire du courant alternatif et continu, ils proposent des solutions d\u00e9di\u00e9es pour toutes les exigences d&#8217;application.\u00a0<\/p>\r\n<p>Les disjoncteurs \u00e0 bo\u00eetier moul\u00e9 peuvent \u00eatre utilis\u00e9s dans les installations civiles et industrielles basse tension avec un courant de fonctionnement de 1 \u00e0 3 200 A. La famille SACE T Generation comprend 9 tailles de disjoncteurs en versions tripolaires ou t\u00e9trapolaires :<br \/>&#8211; XT1, XT2, XT3 et XT4 jusqu&#8217;\u00e0 250A ;<br \/>&#8211; T4, T5 et T6 jusqu&#8217;\u00e0 1000A<br \/>&#8211; T7 et T8 jusqu&#8217;\u00e0 3200A.<\/p>\r\n<p>Le pouvoir ultime de coupure en court-circuit (Icu) \u00e0 415 V varie de 18 kA \u00e0 200 kA, ou jusqu&#8217;\u00e0 100 kA pour 690 V.<\/p>\r\n<p>Les gammes suivantes sont disponibles :<br \/>&#8211; Disjoncteurs pour distribution d&#8217;\u00e9nergie AC et DC ;<br \/>&#8211; Disjoncteurs pour s\u00e9lectivit\u00e9 de zone\u00a0;<br \/>&#8211; Disjoncteurs pour la protection des moteurs\u00a0;<br \/>&#8211; Disjoncteurs pour applications jusqu&#8217;\u00e0 1 150 V AC et 1 000 V DC ;<br \/>&#8211; Interrupteurs-sectionneurs.<\/p>\r\n<p>Tous les disjoncteurs SACE T Generation peuvent \u00eatre am\u00e9lior\u00e9s avec une vaste gamme d&#8217;accessoires standardis\u00e9s. Cette commodit\u00e9 permet non seulement de r\u00e9duire les stocks, mais cr\u00e9e une solution extr\u00eamement flexible et facile \u00e0 g\u00e9rer.<\/p>\r\n<p>Les disjoncteurs SACE G\u00e9n\u00e9ration T peuvent \u00eatre \u00e9quip\u00e9s de d\u00e9clencheurs thermomagn\u00e9tiques, uniquement magn\u00e9tiques ou \u00e9lectroniques, tous interchangeables.<\/p>\r\n<p>Les instructions de montage \u00e9tant simples, les d\u00e9clencheurs peuvent \u00eatre remplac\u00e9s rapidement et facilement\u00a0; m\u00eame sur le terrain.<\/p>\r\n<p>Tout cela rend les disjoncteurs tr\u00e8s faciles \u00e0 utiliser avec des \u00e9conomies consid\u00e9rables gr\u00e2ce \u00e0 une gestion rationalis\u00e9e des stocks.<\/p>\r\n\r\n<figure class=\"wp-block-image\"><img alt=\"\" loading=\"lazy\" decoding=\"async\" width=\"730\" height=\"371\" class=\"wp-image-674\" src=\"https:\/\/www.qbkg.com\/wp-content\/uploads\/2022\/12\/TMAX-100.jpg\" alt=\"\" srcset=\"https:\/\/www.xdele.cn\/wp-content\/uploads\/2022\/12\/TMAX-100.jpg 730w, https:\/\/www.xdele.cn\/wp-content\/uploads\/2022\/12\/TMAX-100-300x152.jpg 300w\" sizes=\"auto, (max-width: 730px) 100vw, 730px\" \/><\/figure>\r\n<!-- \/wp:paragraph --><!-- wp:post-content --><!-- wp:paragraph -->\r\n<p>SACE T Generation moulded-case circuit-breakers guarantee an extremely high-performance level while being progressively smaller in size, simple to install and able to provide increasingly better safety guarantees for the operator.<\/p>\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n<p>In addition to being ideal for the secondary distribution of alternate and direct current, they feature dedicated solutions for all application requirements.\u00a0<\/p>\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n<p>Moulded-case circuit-breakers can be used in low voltage civil and industrial installations with 1 to 3200 A operating current. The SACE T Generation family includes 9 circuit-breaker sizes in three- or four-pole versions:<br \/>&#8211; XT1, XT2, XT3 and XT4 up to 250A;<br \/>&#8211; T4, T5 and T6 up to 1000A<br \/>&#8211; T7 and T8 up to 3200A.<\/p>\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n<p>The ultimate short-circuit breaking capacity (Icu) at 415V ranges from 18kA to 200kA, or up to 100kA for 690V.<br \/><br \/>The following ranges are available:<br \/>&#8211; Circuit-breakers for AC and DC power distribution;<br \/>&#8211; Circuit-breakers for zone selectivity;<br \/>&#8211; Circuit-breakers for motor protection;<br \/>&#8211; Circuit-breakers for up to 1150V AC and 1000V DC applications;<br \/>&#8211; Switch-disconnectors.<\/p>\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n<p>All SACE T Generation circuit breakers can be enhanced with a vast range of standardized accessories. This convenience not only cuts down on inventory but creates an extremely flexible and easily managed solution.<br \/><br \/>SACE T Generation circuit-breakers can be equipped with thermomagnetic, solely magnetic or electronic trip units, all of which are interchangeable.<br \/><br \/>Since assembly instructions are simple, trip units can quickly and easily be replaced; even in the field.<br \/><br \/>All this makes the circuit-breakers very easy to operate with considerable savings due to rationalized stock management.<\/p>\r\n<!-- \/wp:paragraph -->\r\n<p>&nbsp;<\/p>\r\n<!-- wp:image {\"id\":674} -->\r\n<figure class=\"wp-block-image\"><img alt=\"\" loading=\"lazy\" decoding=\"async\" width=\"730\" height=\"371\" class=\"wp-image-674\" src=\"https:\/\/www.qbkg.com\/wp-content\/uploads\/2022\/12\/TMAX-100.jpg\" alt=\"\" srcset=\"https:\/\/www.xdele.cn\/wp-content\/uploads\/2022\/12\/TMAX-100.jpg 730w, https:\/\/www.xdele.cn\/wp-content\/uploads\/2022\/12\/TMAX-100-300x152.jpg 300w\" sizes=\"auto, (max-width: 730px) 100vw, 730px\" \/><\/figure>\r\n<!-- \/wp:image --><!-- \/wp:post-content -->","protected":false},"excerpt":{"rendered":"<p>SACE T Generation moulded-case circuit-breakers guarantee an extremely high-performance level while being progressively smaller in size, simple to install and able to provide increasingly better safety guarantees for the operator. In addition to being ideal for the secondary distribution of alternate and direct current, they feature dedicated solutions for all application requirements.\u00a0 Moulded-case circuit-breakers can [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":676,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_seopress_robots_primary_cat":"","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","footnotes":""},"categories":[15],"tags":[],"class_list":["post-673","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-mccb"],"_links":{"self":[{"href":"https:\/\/www.xdele.cn\/en\/wp-json\/wp\/v2\/posts\/673","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.xdele.cn\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.xdele.cn\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.xdele.cn\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.xdele.cn\/en\/wp-json\/wp\/v2\/comments?post=673"}],"version-history":[{"count":0,"href":"https:\/\/www.xdele.cn\/en\/wp-json\/wp\/v2\/posts\/673\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.xdele.cn\/en\/wp-json\/wp\/v2\/media\/676"}],"wp:attachment":[{"href":"https:\/\/www.xdele.cn\/en\/wp-json\/wp\/v2\/media?parent=673"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.xdele.cn\/en\/wp-json\/wp\/v2\/categories?post=673"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.xdele.cn\/en\/wp-json\/wp\/v2\/tags?post=673"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}